Monday 30 January 2012

Start a Assembly of Diesel Generator Set Unit

 

(272). Start a Assembly of Diesel Generator Set Unit

Diesel Generator set is used to generate electricity for meeting the electricity requirement of small establishments such as commercial buildings, Hotels, Railway Stations, Telephone Exchange, Shops etc. when there is a power supply failure from the State Electricity Board or other power supply undertakings.The prime mover of the Generator set will be a diesel engine and the prime mover will be coupled to an alternator (single phase for small units). There will be a control panel to control the on/off operation/change over from mains supply to Generator set supply etc. Generator sets of higher rating has to be started with battery starters. Diesel Generator sets of smaller rating can be started by cranking.



Market Potential
Since power failure is very common in India, this equipment has got good demand. Diesel Generator set of 5 kVA rating is having very good market as it suits to most of the commercial establishments.

Basis and Presumptions
i) The basis for calculation of production capacity has been taken on single shift basis on 75% efficiency.

ii) The maximum capacity utilization on single shift basis for 300 days a year. During first year and second year of operations the capacity utilization is 60% and 80% respectively. The unit is expected to achieve full capacity utilization from the third year onwards.

iii) The salaries and wages, cost of raw materials, utilities, rents, etc. are based on the prevailing rates in and around Coimbatore. These cost factors are likely to vary with time and location.

iv) Interest on term loan and working capital loan has been taken at the rate of 12.5% on an average and amount of loan seek from the financial institution is 75 % of total working capital. This rate may vary depending upon the policy of the financial institutions/agencies from time to time.

v) The cost of machinery and equipments refer to a particular make/model and prices are approximate.

vi) The break-even point percentage indicated is of full capacity utilization.

vii) The project preparation cost etc. whenever required could be considered under pre-operative expenses.

viii) The essential production machinery and test equipment required for the project have been indicated. The unit may also utilize common test facilities available at Electronics Test and Development Centres (ETDCs) and Electronic Regional Test Laboratories (ERTLs) and Regional Testing Centres (RTCs).
  

   
Implementation Schedule
The major activities in the implementation of the project has been listed and the average time for implementation of the project is estimated at 12 months:
Sl. No. Activity Period
(in Months)
1. Preparation of project report 1
2. Registration and other formalities 1
3. Sanction of loan by financial institutions 3
4. Plant and Machinery:
a) Placement of orders
1
b) Procurement 2
c) Power connection/Electrification 2
d) Installation/Erection of machinery/Test Equipment 2
5. Procurement of raw materials 2
6. Recruitment of Technical Personnel etc. 2
7. Trial production 11
8. Commercial production 12
Notes
1. Many of the above activities shall be initiated concurrently.
2. Procurement of raw materials commences from the 8th month onwards.
3. When imported plant and machinery are required, the implementation period of project may vary from 12 months to 15 months.
Technical Aspects

Process of Manufacture
The proposed unit is doing the assembly of diesel generator sets with necessary control panel as per the requirement of the customer.


The load requirement of the customer is studied in consultation with the customer. Any special requirements such as minimum start up period, fluctuations of load etc. are noted. A suitable alternator to meet the load requirement is procured from an alternator manufacturer. A diesel engine suitable for the alternator is also selected and procured from the diesel engine manufacturer. The diesel engine and alternator are coupled and fixed on a frame. A control panel for starting the engine using battery bank, isolating the mains while the alternator is running, disconnecting the alternator when the mains supply is available etc. is designed and assembled as stipulated by the customer. The assembly is tested for fuel efficiency, load capacity of the alternator, operational sequences etc.

The Diesel Generator set is then despatched to the premises of the customer in dismantled condition on in assembled condition depending upon the size of the Diesel Generator set.
Quality Control and Standards
The alternator has to meet the requirements of the customer with regard to voltage, frequency, power etc. and the diesel engine has to conform to IS 10001.

The performance of alternator and diesel engine may be tested at the manufacturers' works before taking delivery. The control panel requires contactors and relays. The contractors and relays shall conform to relevant IS Specification and shall be from a reputed manufacturer.
Production Capacity (per annum)
The actual manufacturing depends up on the orders received and the marketing efforts taken by the unit. The proposed unit will have a capacity to assemble 24 diesel generator sets in a year. For the purpose of financial projections a standard rating of 5 kVA diesel generator set is taken.
Motive Power: 10 KW.
Pollution Control
The Government accords utmost importance to control environmental pollution. The small-scale entrepreneurs should have an environmental friendly attitude and adopt pollution control measures by process modification and technology substitution.

India having acceded to the Montreal Protocol in September 1992, the production and use of Ozone Depleting Substances (ODS) like Chlorofluore Carbon (CFCs), Carbon Tetrachloride, Halons and methyl Chloroform etc. need to be phased out immediately with alternative chemicals/solvents. A notification for detailed Rules to regulate ODS phase out under the Environment Protection Act, 1986 have been put in place with effect from 19th July 2000.

Energy Conservation
With the growing energy needs and shortage coupled with rising energy cost, a greater thrust in energy efficiency in industrial sector has been given by the Govt. of India since 1980s. The Energy Conservation Act, 2001 has been enacted on 18th August 2001, which provides for efficient use of energy, its conservation and capacity building of Bureau of Energy Efficiency created under the Act.
The following steps may help for conservation of electrical energy:

i) Adoption of energy conserving technologies, production aids and testing facilities.

ii) Efficient management of process/manufacturing machineries and systems, QC and testing equipments for yielding maximum Energy Conservation.

iii) Optimum use of electrical energy for heating during soldering process can be obtained by using efficient temperature controlled soldering and de-soldering stations.

iv) Periodical maintenance of motors compressors etc.

v) Use of power factor correction capacitors. Proper selection and layout of lighting system; timely switching on-off of the lights; use of compact fluorescent lamps wherever possible etc.



Financial Aspects
A. Fixed Capital
(i) Land and Building (Rs.)
Built up area 2000 sq/ft.
Rent payable (per month) 6000
(ii) Machinery and Equipments
Sl. No. Description Qty. Rate (Rs.) Amount (Rs.)
1. Pendent operated Electric Hoist 5Ts capacity with supporting frame 1 No. 24200 24200
2. Welding Transformer 2 kVA 1 No. 7000 7000
3. Gas cutting equipment 1 No. 8000 8000
4. Flexible shaft grinder 1 No. 8000 8000
5. Bench Drilling Machine ½" Cap. 1 No. 14000 14000
6. Set of tools such as spanners, Screw drivers, crimping tools etc. 1 No. 16000 16000
7. Resistance load bank for loading the Alternator (10 kW capacity) 1 No. 13000 13000
8. Testing panel for testing the Performance of the Diesel Generator set (Fitted with ammeters, voltmeter, watt meter, Indication lamp etc.) 1 No. 22,000 22,000
Total
112200
9. Electrification and Installation charges (a) 10% of Cost of machinery and equipments 11220
10. Office equipments and furniture 40,000
11. Tools/Jigs/ fixture 20,000
(iii) Pre-operatine expenses
10,000
Total
193420
B. Working Capital (per month)
(i) Salaries and Wages (per month)
Sl. No. Description Qty. Rate (Rs.) Amount (Rs.)
1. Electrical Fitters 1 3500 3500
2. Helper 1 2000 2000
3. Production Supervisor 1 5000 5000
4. Marketing Executive 1 4000 4000
Total
14500
Add 15% Testing Perquisites 2175
Total
16675
Say
16700
(ii) Raw Material Required (per month)
Sl. No. Description Qty. Rate (Rs.) Amount (Rs.)
1. Diesel Engine 7.5 HP 2 Nos. 9600 19200
2. Alternator 5 kVA single phase, 230 V, 50 Hz 2 Nos. 7000 14000
3. Relays and Contractors 2 sets 3000 6000
4. PVC insulated cable for Control Panel wiring 1 Coil 850 850
5. M.S. channels, bolts, nuts and M.S. Plates LS - 4000
6. Sheet metal enclosure for Control Panel 2 Nos. 1200 2400
7. Other misc. items such as crimping lugs, hardware etc. LS - 600
Total
47050
(iii) Utilities (per month)
Sl. No. Description Amount (Rs.)
1. Power 4500
2. Water 350
Total
4850
(iv) Other Contingent Expenses (per month)
Sl. No. Description Amount (Rs.)
1 Sales expenditure 3000
2 Consumable Stores 3500
3 Postage and Stationery 2000
4 Telephone 2000
5 Rent 6000
6 Misc. Expenditure 1500
Total
18000
(v) Recurring Expenditure (per month) (i+ii+iii+iv) 86600
(vi) Working Capital Requirement (Rs.)
The approximate amount of working capital requirement is taken as 3 months recurring expenditure (i.e. 3 × 86600) 259800
C. Total Capital Investment
(i) Fixed Capital Rs. 193420
(ii) Working Capital on 3 months basis Rs. 259800
Total
Rs. 453220
Financial Analysis
(1) Cost of Production (per annum) (Rs.)
(a) Total recurring expenditure 1039200
(b) Depreciation on machinery and equipment @ 10% 11220
(c) Depreciation on tools, jigs and fixtures @ 25% 5000
(d) Depreciation of office equipment, furniture @ 20% 8000
(e) Interest on 75 % total capital investment @ 12.5% 42490
Total
1105910
Say
1105910
(2) Turn over (per annum)
Item Qty. (Nos.) Rate/Unit (Rs.) Total Sales (Rs.)
Diesel Generator Set 5 kVA with control Panel 24 53000 1272000

(3) Profit (per annum) (Before Taxes) Rs. 166090

(4) Net Profit Ratio
=
Profit per annum × 100
-------------------------
Sales per annum
=
166090 × 100
--------------------
1272000
=
13.06%
(5) Rate of Return
=
Profit per annum × 100
----------------------------
Total capital investment
=
1,66,090 × 100
----------------------
4,53,220
=
36.65%
(6) Break-even Point
Fixed Cost (per annum) (Rs.)
Rent 72000
Depreciation on machinery and equipment @ 10% 11220
Depreciation on tools, jigs and fixtures @ 25% 5000
Depreciation on office equipment, furniture @ 20% 8000
Interest on total capital investment @ 16% 42490
40% Salaries and wages 80160
40% other contingent expenses and utilities (excluding rent) 80880
Total
299750
Say
2,99,750

B.E.P. = Fixed cost × 100
--------------------
Fixed cost + Profit
= 2,99,750 × 100
---------------------
2,99,750 + 1,66090
= 64.35%
Additional Information
a. The Project Profile may be modified/tailored to suit the individual entrepreneurship qualities/ capacity, production Programme and also to suit the locational characteristics, wherever applicable.

b. The Electrical Technology is undergoing rapid strides of change and there is need for regular monitoring of the national and international technology scenario. The unit may, therefore, keep abreast with the new technologies in order to keep them in pace with the developments for global competition.
c. Quality today is not only confined to the product or service alone. It also extends to the process and environment in which they are generated. The ISO 9000 defines standards for Quality Management Systems and ISO 14001 defines standards for Environmental Management System for acceptability at international level. The unit may therefore adopt these standards for global competition.

d. The margin money recommended is 25% of the working capital requirement at an average. However, the percentage of margin money may vary as per bank's discretion.


Addresses of Machinery and Equipment Suppliers
1. M/s. Automation Props Test Equipment (Elec.) Pvt. Limited
Dr. Annie Besant Road,
Worli, Mumbai - 400 018.
(For Test Panel)

2. M/s. Meco Instrument Pvt. Ltd.
301, Bharat Industrial Estate,
T.J. Road, Sewree, Mumbai- 400 015
(For Measuring Instruments)

3. Local dealers
(For Tool kits)

Addresses of Components and Parts Suppliers
1. M/s. Jyothi Limited
Alternative Division,
P.O. Chemical Industries, Vadodara
(For alternates)

2. M/s. Crompton Greaves Ltd.
Marketing Office: 1,
Dr. V.B. Gandhi Nagar, Fort,
Mumbai - 400 023.
(For alternates)

3. M/s. J.P. Engineering Works
A-70, G.T. Karnal Road,
Industrial Area,
Delhi - 110033.
(For Alternates)

4. M/s. Kirloskar Cummus Ltd. Pune
(For Diesel Engine)

5. M/s. Mono tex Agency
165, Dr. Nanjappa Road,
Coimbatore - 12.
(For Diesel Engine)

6. M/s. Asia Electric Company Katara Mansion,
Dr. A.B. Road, Worli,
Mumbai- 400 018.
(For Control Panel Assembly)


20 comments:

  1. I came accross this website to read more info on this great product: http://www.directindustry.com/industrial-manufacturer/diesel-generator-set-72259.html

    ReplyDelete
  2. Thanks for the post, I will look forward to see more posts from your blog and and also about
    fpt generating set Generators

    ReplyDelete
  3. Thanks for the post, I will look forward to see more posts from your blog and and also about
    ivco generators dubai Generators.

    ReplyDelete
  4. Yeah I agree that Generator sets are used to accomplish the electricity requirements of small establishments like homes and shops etc. I strongly feel that th honda generator 3000 is the best for this purpose. I am using it at my shop and it is perfect for my power backup needs.

    ReplyDelete
  5. Interesting and valuable Post.
    Generator is most famous energy system.
    Thanks for Sharing ! Cummins generator

    ReplyDelete
  6. Diesel Generators Information was very good to read. Thanks for sharing this post. Keep Sharing.


    If you want to check more details on Used diesel Generators Click Here Used Diesel Generators

    ReplyDelete
  7. Great Article 365 Days used diesel generators.!This information you provided in the blog that was really unique I love it!!, Thanks for sharing such a great blog . Keep posting.

    ReplyDelete
  8. Awesome informations on diesel generators.Thanks for sharing this informations. Do more posts regarding this topic. Thanks for sharing.

    If you want to check more details on used diesel generators Clcik here Used generators

    ReplyDelete
  9. I am happy to find this post Very useful for me, as it contains lot of information. I Always prefer to read The Quality and glad I found this thing in you post. Thanks generator suppliers sri lanka

    ReplyDelete
  10. Thanks for the post, I will look forward to see more posts from your blog and and also about
    DG Set on rent in Vadodara Generators.

    ReplyDelete
  11. Generator Manufacturers Shipping Service? Our industry knowledge and expertise allow us to support and ship generators safely. With us, don't worry about the generator shipping as we can deliver everything nationally and internationally.

    ReplyDelete
  12. Generator suppliers
    This article is amazing. It helped me a lot. Sir, keep up the good work. We are always with you and look forward to your new interesting articles.

    ReplyDelete
  13. Electric & Diesel Generator Suppliers
    Yes, this is a good post without any doubt. You really do a great job. I am inspired by you, so keep it up!

    ReplyDelete
  14. Thank you for posting this excellent information..it is very useful to me..!

    Diesel Generator Rental

    ReplyDelete
  15. Thanks for sharing this information. To know more click on manufacturers of Stud in Vijayawada

    ReplyDelete

START A BUSINESS OF HERBAL LASSI

START A BUSINESS OF HERBAL LASSI INTRODUCTION Lassi, as such has very good nutritional value. Lassi is considered to be even b...